Skip to main content
Loading…
This section is included in your selections.

The map below shows which block faces require or encourage pedestrian-oriented uses. Where not specified, pedestrian-oriented uses are permitted provided they are listed in the allowed uses table for the zone. 

Map 13.4
Pedestrian-Oriented Block Faces


Note: Online users may click the map for a full-size version in pdf format.

Figure 21.13.140A

Building Placement

Table 21.13.140A

Building Placement

MDD1 and MDD2

MDD3

MDD4

MDD5

Build-to lines and setbacks

🅐 and 🅑

Build-to line (BTL): 0 ft
BTL defined by facade on pedestrian-supportive block faces: min. 80%
BTL defined by facade on other block faces: min. 50%

🅒 and 🅓

Min. setback: 0 ft.

Park setback: min. 5 ft from back of perimeter path shoulder

Minimum setbacks:
• Front: 15 ft
• Side / interior: 5 ft
• Side street: 10 ft
• Rear: 10 ft
Alley: 4ft

🅐

Min. setback: 30 ft

🅑 , 🅒 , 🅓

Min. setbacks: 10 ft

NE 68th St:

BTL: 0 ft
BTL defined by facade: 50%

Park setback: min. 5 ft from back of perimeter path shoulder

🅐

Facade zone: 5-15 ft

• Min facade within zone: 50%

Buildings fronting NE 65th St shall measure setback from back of landscape strip

🅑

Facade zone: 5-15 ft

Min facade within zone: 50%

🅒

Min. setback: 5 ft; no minimum if abutting uses are both residential or both non-residential

🅓

Min. setback: 10 ft

Alley setback: 4 ft minimum

Park
Facade zone: 15-25 ft from back of perimeter path shoulder


• Min facade within zone: 50% (assumes 12-ft shared-use path along park edge)

Structures in required setbacks

Improvements less than 30 inches above grade, including decks, patios, walks and driveways are permitted in setbacks. Fences, landscaping, flagpoles, street furniture, transit shelters, and slope stability structures are permitted in setback areas, provided that all other applicable requirements are met. No other structures, including accessory structures, are permitted in setback areas.

Orientation

Building fronts shall be oriented toward pedestrian-oriented block faces; where the building abuts no pedestrian-oriented block face the building front shall face the highest classification street


Building services such as loading/unloading and trash collection shall be oriented or accessed from the same block face as the primary vehicle access

Building fronts shall be oriented toward 180th Pl NE


Building services such as loading/unloading and trash collection shall be oriented or accessed from the same block face as the primary vehicle access

Building fronts shall be oriented toward the highest classification street


Building services such as loading/unloading and trash collection shall be oriented or accessed from the same block face as the primary vehicle access

• Primary building fronts shall be oriented toward: blocks 1-2: NE 67th St; blocks 3-8: 177th Ave NE or NE 63rd St


• Secondary building fronts shall be oriented toward: blocks 1-2: Marymoor Park; blocks 3, 4, 6, 8: Marymoor Park; blocks 5, 7: NE 65th St


Building services such as loading/unloading and trash collection shall be oriented or accessed from the same block face as the primary vehicle access


• See Map 13.1 Marymoor Design District Map for block locations

Figure 21.13.140B

Ground Floor Requirements

Figure 21.13.140C

Upper-story Setbacks

Table 21.13.140B

Building Form

MDD1

MDD2

MDD3

MDD4

MDD5

Maximum Height 🅔

6 stories except in Height Overlay Area (see Map 13.5,Height Overlay Area)

5 stories

5 stories

4 stories except in Height Overlay Area (see Map 13.5,Height Overlay Area)

5 stories except in Height Overlay Area (see Map 13.5,Height Overlay Area)


Upper-story Setbacks

See 21.13.140.A,Upper-story Setbacks

No standard

See 21.13.140.A,Upper-story Setbacks

Ground floor finish level 🅕

Residential use: 2 to 5 feet above sidewalk grade where front entrance faces a street.


• Non-residential use: maximum 6” above sidewalk grade

Residential use: 2 to 5 feet above sidewalk grade where front entrance faces a street, except as noted in RZC 21.13.140.B,

Ground Floor Uses


• Non-residential use: maximum 6” above sidewalk grade

No standard

• Residential ground-floor use: 2 to 5 feet above sidewalk grade where front entrance faces a street.


• Non-residential ground-floor use: maximum 6” above sidewalk grade

Ground floor height (floor to floor) 🅖

• Non-residential use: minimum 15 feet

Non-residential use: minimum 15 feet, except as noted in RZC 21.13.140.B,Ground Floor Uses 

No standard

Non-residential use: minimum 15 feet

Ground floor uses

Residential uses prohibited where pedestrian-oriented uses are encouraged or required


Pedestrian-oriented uses encouraged as part of any light rail station plaza development to activate the plaza

Residential uses prohibited where pedestrian-oriented uses are encouraged or required, except as noted in RZC 21.13.140.B,Ground Floor Uses

No standard

Maximum distance between ground-floor non-residential entries

50 ft

No standard

50 ft

Minimum ground floor non-residential depth 🅗

20 ft

No standard

20 ft

Residential privacy

The standards in RZC 21.62.020.F.1,Residential Standards, shall apply.

The standards in RZC 21.62.020.F.1, Residential Standards, shall apply.
The residential space designed for future conversion to pedestrian-oriented uses is exempt from this subsection.

The standards in RZC 21.62.020.F.1,Residential Standards, shall apply.

No standard

The standards in RZC 21.62.020.F.1,Residential Standards, shall apply.

A. Upper-story setbacks. All building faces facing a street or path shall integrate average minimum upper-story building setbacks to reduce the perceived scale of building facades, increase the amount of light and air to adjacent streets and paths, promote modulation of building facades that adds variety and provides visual interest, encourage the integration of courtyards and open space; and allow for flexibility in the design of buildings.

1. The average minimum upper-story building setbacks shall comply with the following:

a. From the roof edge of the second story  🅘,  buildings shall step back at a 68-degree angle 🅙 up to the roof of the top story of fifth story 🅚 , whichever is lower.

b. From the roof edge of the fifth story 🅚, buildings shall step back at a 32-degree angle 🅛 up to the maximum height limit.

2. Calculations for determining compliance with these standards shall consider the development's first 30 feet of depth 🅜 along streets and paths.

3. Portions of building may project beyond the average setback 🅝 provided the block frontage as a whole complies with the minimum average.

B. Ground floor uses.

1. Where pedestrian-oriented ground floor uses are required as shown in Map 13.4, Pedestrian-Oriented Block Faces, the following requirements must be met, in addition to the design requirements found in RZC Article IV, Design Standards.

a. A minimum of 50 percent of the linear sidewalk-level facade shall be occupied by pedestrian-oriented uses and should be continuous.

b. Up to 50 percent of the linear sidewalk-level frontage may be designed to accommodate future conversion to pedestrian-oriented uses. Any uses other than residential may be permitted until conversion of the space.

2. Where pedestrian-oriented (non-residential) ground floor uses are encouraged, 100 percent of the linear sidewalk-level facade shall be designed to accommodate future conversion to pedestrian-oriented uses. Any uses other than residential uses are permitted.

3. Where pedestrian-oriented uses are encouraged, a minimum of 50 percent of the linear sidewalk-level facade shall be designed to accommodate future conversion to pedestrian-oriented uses and shall be designed at a maximum of 6 inches above sidewalk grade. Residential uses are permitted. The ground-floor height standard of 15 feet does not apply in this area.

4. In locations where ground floor residential uses are permitted, the units shall be set back a minimum of ten feet from the sidewalk edge. The Administrator may consider alternative design solutions that retain resident privacy while enhancing the pedestrian environment on the sidewalk.

Map 13.5

Height Overlay Area


Note: Online users may click the map for a full-size version in pdf format.

(Ord. 2883; Ord. 2958)

Effective on: 4/27/2019