Skip to main content
Loading…
This section is included in your selections.

A. Lighting levels for outdoor performance areas, sport and recreation facilities, and play fields shall not exceed by more than five percent the Illuminating Engineering Society of North America (IESNA) published standards for the proposed activity.

B. Where playing fields or other special activity areas are to be illuminated, lighting fixtures shall be mounted, aimed, and shielded so that their beams fall within the primary playing area and immediate surroundings, and so that no direct illumination is directed off the site.

C. The main lighting shall be turned off as soon as possible following the end of the event. The main lighting shall not remain on longer than 30 minutes following the end of the event. Where feasible, a low-level lighting system shall be used to facilitate patrons leaving the facility, cleanup, nighttime maintenance, and other closing activities. Illumination of the low-lighting system shall be as provided in RZC 21.34.120, Mounting and Illumination Standards Table, of this chapter.

Effective on: 4/16/2011