A. Lighting of such areas shall not be used to attract attention to the business.

B. Lighting levels shall be as set forth in RZC 21.34.120, Mounting and Illumination Standards Table, of this chapter.

C. In order to minimize the extent of direct glare, light fixtures shall be mounted in one of the following manners:

1. On canopies and recessed so that the lens cover is recessed or flush with the bottom surface (ceiling) of the canopy or shielded by the fixture or the edge of the canopy so that light is restrained to 85 degrees or less from vertical; or

2. As indirect lighting where light is beamed upward and then reflected down from the underside of the canopy. When this method is used, light fixtures must be shielded so that direct illumination is focused exclusively on the underside of the canopy.

D. Lights shall not be mounted on the top or sides (fascias) of the canopy. The sides (fascias) of the canopy shall not be illuminated in a manner other than that prescribed under the section of these regulations regulating signs.

E. Illumination of areas around service station pump islands shall be as provided in RZC 21.34.120, Mounting and Illumination Standards Table, of this chapter. At the discretion of the Technical Committee, increased lighting levels may be permitted for enhanced security purposes only.

Effective on: 4/16/2011